<?xml version="1.0" encoding="utf-8" ?><rss version="2.0" xmlns:tt="http://teletype.in/" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:media="http://search.yahoo.com/mrss/"><channel><title>@uvmetre</title><generator>teletype.in</generator><description><![CDATA[gloss meter is used to measure the surface gloss of the objects]]></description><link>https://teletype.in/@uvmetre?utm_source=teletype&amp;utm_medium=feed_rss&amp;utm_campaign=uvmetre</link><atom:link rel="self" type="application/rss+xml" href="https://teletype.in/rss/uvmetre?offset=0"></atom:link><atom:link rel="next" type="application/rss+xml" href="https://teletype.in/rss/uvmetre?offset=10"></atom:link><atom:link rel="search" type="application/opensearchdescription+xml" title="Teletype" href="https://teletype.in/opensearch.xml"></atom:link><pubDate>Tue, 24 Nov 2026 13:12:05 GMT</pubDate><lastBuildDate>Tue, 24 Nov 2026 13:12:05 GMT</lastBuildDate><item><guid isPermaLink="true">https://teletype.in/@uvmetre/zuIvOEVta</guid><link>https://teletype.in/@uvmetre/zuIvOEVta?utm_source=teletype&amp;utm_medium=feed_rss&amp;utm_campaign=uvmetre</link><comments>https://teletype.in/@uvmetre/zuIvOEVta?utm_source=teletype&amp;utm_medium=feed_rss&amp;utm_campaign=uvmetre#comments</comments><dc:creator>uvmetre</dc:creator><title>Note for UV disinfection lamp</title><pubDate>Wed, 29 Jul 2020 05:59:00 GMT</pubDate><description><![CDATA[Note for UV disinfection lamp: 1. When using ultraviolet disinfection lamps, people, animals and plants must leave the scene. 2. don't stare at the ultraviolet disinfection lamp for an extended time. Ultraviolet rays can damage human skin and mucous membranes to a particular extent. When using ultraviolet disinfection lamps, concentrate to protection. The eyes must not look directly at the ultraviolet source, otherwise the eyes are going to be hurt. 3. When disinfecting items with ultraviolet disinfection lamps, spread or hang the things to expand the irradiation surface. The effective distance is one meter, and therefore the irradiation is about half-hour . 4. When using ultraviolet disinfection lamps, the environment should be kept...]]></description><content:encoded><![CDATA[
  <p>Note for UV disinfection lamp:<br />1. When using ultraviolet disinfection lamps, people, animals and plants must leave the scene.<br />2. don&#x27;t stare at the ultraviolet disinfection lamp for an extended time. Ultraviolet rays can damage human skin and mucous membranes to a particular extent. When using ultraviolet disinfection lamps, concentrate to protection. The eyes must not look directly at the ultraviolet source, otherwise the eyes are going to be hurt.<br />3. When disinfecting items with ultraviolet disinfection lamps, spread or hang the things to expand the irradiation surface. The effective distance is one meter, and therefore the irradiation is about half-hour .<br />4. When using ultraviolet disinfection lamps, the environment should be kept clean. There should be no dust and water mist within the air. When the indoor temperature is less than 20 degrees Celsius or the ratio exceeds 50%, the irradiation time should be extended. After scrubbing the ground , wait until the ground is dry before disinfecting with ultraviolet .<br />5. After using the ultraviolet disinfection lamp, remember to ventilate for half-hour before entering the space .<br />6. Before using the ultraviolet , make certain to see and make sure that the intensity of the ultraviolet are able to do the sterilization effect. The intensity of ultraviolet is that the main think about the sterilization effect of ultraviolet . The radiation intensity of the ultraviolet source will gradually decrease during the utilization process. so as to make sure the disinfection effect of the ultraviolet source and more effectively prevent the occurrence of nosocomial infections, it&#x27;s very necessary to regularly check the intensity of the ultraviolet source . The wavelength of the ultraviolet germicidal lamp is usually 253.7nm, and therefore the UVC <a href="https://www.linshangtech.com/productlist3/" target="_blank">uv light intensity meter</a> is required to detect the ultraviolet intensity of the germicidal lamp.<br />Linshang LS126C uv light intensity meter is an ultraviolet irradiance meter dedicated to energy detection of ultraviolet germicidal lamps. The spectral response range is 230nm-280nm, and therefore the peak wavelength is 254nm. The instrument is provided with a 1-meter hook, which may be hung vertically under the lamp tube very conveniently. The instrument comes with a Bluetooth function, which may be linked to a mobile dedicated APP to understand wireless monitoring data from a particular distance. Avoid being burned by ultraviolet rays when viewing data on site, and truly save data automatically for unattended measurement. Brings convenience to your UV energy monitoring.</p>

]]></content:encoded></item><item><guid isPermaLink="true">https://teletype.in/@uvmetre/7FIP22PuP</guid><link>https://teletype.in/@uvmetre/7FIP22PuP?utm_source=teletype&amp;utm_medium=feed_rss&amp;utm_campaign=uvmetre</link><comments>https://teletype.in/@uvmetre/7FIP22PuP?utm_source=teletype&amp;utm_medium=feed_rss&amp;utm_campaign=uvmetre#comments</comments><dc:creator>uvmetre</dc:creator><title>UV sterilization</title><pubDate>Thu, 23 Jul 2020 01:42:29 GMT</pubDate><description><![CDATA[Ultraviolet rays are divided into three types according to wavelength: long-wave ultraviolet, medium-wave ultraviolet and short-wave ultraviolet. The specific ultraviolet intensity can be detected with an ultraviolet radiation meter.]]></description><content:encoded><![CDATA[
  <p>Ultraviolet rays are divided into three types according to wavelength: long-wave ultraviolet, medium-wave ultraviolet and short-wave ultraviolet. The specific ultraviolet intensity can be detected with an ultraviolet radiation meter.</p>
  <p>　　 Long-wave ultraviolet, also known as UVA, with a wavelength of 315-400nm. The ultraviolet rays in the sun are almost all UVA, most of the UVA can reach the surface of the earth, and it has the effect of destroying elastic fibers and collagen fibers on people&#x27;s skin, which is to tan people&#x27;s skin. But there is no bactericidal effect.</p>
  <p>　　 Medium-wave ultraviolet, also known as UVB, wavelength 280-315nm. A small part of sunlight is UVB, because most of the UVB in sunlight is absorbed by the ozone layer, and less than 2% can reach the surface of the earth. UVB ultraviolet rays have erythema effects on the human body, which can cause skin swelling and molting. There is also no bactericidal effect.</p>
  <p>　　 Short-wave ultraviolet, also known as UVC, with a wavelength of 200-280nm, is also known as short-wave sterilizing ultraviolet. Ultraviolet rays in sunlight do not have the UVC band. This wavelength of ultraviolet rays is extremely harmful to the human body. The wavelength is short and is completely absorbed by the ozone layer. UVC has a strong sterilization ability, and the ultraviolet germicidal lamp emits UVC.</p>
  <p>　　 Not all ultraviolet rays have a bactericidal effect, only certain wavelengths have this function. The <a href="https://www.linshangtech.com/tech/how-to-select-the-best-uv-light-meter-for-your-application-tech1166.html" target="_blank">UV light meter</a> is used to detect the actual radiation intensity of the ultraviolet germicidal lamp to help people determine whether it meets the requirements for disinfection and sterilization.</p>
  <p>Regarding the radiation intensity of the germicidal lamp, in accordance with the requirements of the &quot;Disinfection Technical Specification&quot;, the radiation intensity of the new lamp should be more than 100μW/cm² (at a distance of 1m) to be monitored by the UV light meter LS126C, which is qualified, and it is in use The low radiation intensity of the lamp should reach 70μW/cm² and it can be used temporarily, but the irradiation time should be extended. Because high-strength short-time or low-strength long time can achieve the same sterilization effect. If the radiation intensity of the lamp tube is lower than 40μW/cm² by using an ultraviolet irradiance meter, it will not have a satisfactory sterilization effect if the irradiation time is extended, and the use should be stopped.</p>

]]></content:encoded></item><item><guid isPermaLink="true">https://teletype.in/@uvmetre/534C_NyJ9</guid><link>https://teletype.in/@uvmetre/534C_NyJ9?utm_source=teletype&amp;utm_medium=feed_rss&amp;utm_campaign=uvmetre</link><comments>https://teletype.in/@uvmetre/534C_NyJ9?utm_source=teletype&amp;utm_medium=feed_rss&amp;utm_campaign=uvmetre#comments</comments><dc:creator>uvmetre</dc:creator><title>Paint film performance</title><pubDate>Wed, 22 Jul 2020 03:13:01 GMT</pubDate><description><![CDATA[Paint film performance: 1. Appearance of the coating film: refers to whether the coating film is smooth, whether there are particles, bubbles, flowers, construction marks, etc. 2. Gloss: The parameter of the ability of Henry paint film to reflect light. Gloss is a very significant feature of paint film, which has a great influence on the decorative performance of paint. High-gloss paint is easy to show the defects of the substrate, so it has higher requirements for the flatness and roughness of the substrate. 3. Hardness: Hardness refers to the resistance of the paint film to foreign objects invading its surface. The hardness of the paint film is one of the important properties of its mechanical strength. Coating thickness gauge can...]]></description><content:encoded><![CDATA[
  <p>Paint film performance:<br />1. Appearance of the coating film: refers to whether the coating film is smooth, whether there are particles, bubbles, flowers, construction marks, etc.<br />2. Gloss: The parameter of the ability of Henry paint film to reflect light. Gloss is a very significant feature of paint film, which has a great influence on the decorative performance of paint. High-gloss paint is easy to show the defects of the substrate, so it has higher requirements for the flatness and roughness of the substrate.<br />3. Hardness: Hardness refers to the resistance of the paint film to foreign objects invading its surface. The hardness of the paint film is one of the important properties of its mechanical strength. <a href="https://www.linshangtech.com/tech/commonly-used-electronic-thickness-gauge-supplier-price-classification-tech1228.html" target="_blank">Coating thickness gauge</a> can be used to test the paint film thickness.<br />4. Transparency: The paint film shows the degree of clarity of the substrate, the effect of a paint with good transparency has a strong three-dimensional effect, and the dark-colored board has a higher requirement for transparency.<br />5. Hand feeling: The lubricating feeling of touching the paint film by hand after the paint film has dried.<br />The thickness standard of the paint film bai is based on the national standard construction specification. When the design is not required, the deviation of the dry film thickness of the paint is -25 microns. Then the allowable deviation of each layer is -5 microns, which is the construction acceptance specification.<br />&quot;When the design is not required, the deviation is -25 microns. However, if the design requires it, the spraying thickness can only be greater than or equal to the design required thickness. The unit measuring point can have a thickness lower than the design requirement, but the measurement The average value of the points must be greater than or equal to the design requirements.<br />According to the national standard &quot;GB1768-(79)88 Paint Film Abrasion Resistance Test Method&quot;, the JM-1 type paint film abrasion tester is used. After a certain number of rotations, the weight loss of the paint film is used to express its abrasion resistance.<br />Because the weight loss method is not affected by the thickness of the paint film, the smaller the weight loss, the better the wear resistance for the same load and rotation. It is more suitable for measuring road marking paint and floor paint.</p>

]]></content:encoded></item><item><guid isPermaLink="true">https://teletype.in/@uvmetre/lTXu70ABz</guid><link>https://teletype.in/@uvmetre/lTXu70ABz?utm_source=teletype&amp;utm_medium=feed_rss&amp;utm_campaign=uvmetre</link><comments>https://teletype.in/@uvmetre/lTXu70ABz?utm_source=teletype&amp;utm_medium=feed_rss&amp;utm_campaign=uvmetre#comments</comments><dc:creator>uvmetre</dc:creator><title>UV energy meter detect high pressure mercury lamp</title><pubDate>Tue, 21 Jul 2020 00:57:27 GMT</pubDate><description><![CDATA[Since the application is so wide, the production of high-pressure mercury lamps will be very professional and rigorous. When it is necessary to know whether the energy and intensity of the high-pressure mercury lamps meet the requirements of industrial production, there is always an instrument for testing, and the UV energy meter is in Here plays an important role. It is said that using a UV energy meter to measure the energy and intensity of a high-pressure mercury lamp is good. Linshang Technology has developed two professional ultraviolet energy meters, S120 and S130, specifically for measuring high-pressure mercury lamps. So what are the advantages of these UV energy meters? For those, I will explain them one by one below...]]></description><content:encoded><![CDATA[
  <p>Since the application is so wide, the production of high-pressure mercury lamps will be very professional and rigorous. When it is necessary to know whether the energy and intensity of the high-pressure mercury lamps meet the requirements of industrial production, there is always an instrument for testing, and the UV energy meter is in Here plays an important role.<br />It is said that using a UV energy meter to measure the energy and intensity of a high-pressure mercury lamp is good. Linshang Technology has developed two professional ultraviolet energy meters, S120 and S130, specifically for measuring high-pressure mercury lamps. So what are the advantages of these UV energy meters? For those, I will explain them one by one below.<br />Advantages of S120 and S130 UV energy meters:<br />One: wide measurement range<br />LS120 <a href="https://www.linshangtech.com/tech/how-to-choose-right-uv-radiometer-tech1229.html" target="_blank">UV energy meter</a> is a domestic UV energy meter that can test energy, power, temperature, and time at the same time, with curve display, data export and test report printing functions.<br />2: Precision and data diversity<br />The instrument will collect spectrum data at a high rate, reaching 2048 times per second, and simultaneously detect the power and energy values ​​and display the power curve, displaying the data of the current test light source in all directions.<br />Three: Authoritative certification<br />The data obtained from the LS130 test can be guaranteed to pass the inspection by the national authority.<br />Four: heat resistance and large capacity<br />The instrument adopts a heat-resistant metal shell, which can work in an environment of up to 100 degrees Celsius for a long time and is suitable for more test occasions. The large internal memory can store more than 60,000 test data.<br />Such a powerful UV energy meter has excellent support for the field of high-pressure mercury lamps. When you need to equip the high-pressure mercury lamp with a UV energy meter, please look for Linshang Technology.</p>

]]></content:encoded></item><item><guid isPermaLink="true">https://teletype.in/@uvmetre/lG4316G2M</guid><link>https://teletype.in/@uvmetre/lG4316G2M?utm_source=teletype&amp;utm_medium=feed_rss&amp;utm_campaign=uvmetre</link><comments>https://teletype.in/@uvmetre/lG4316G2M?utm_source=teletype&amp;utm_medium=feed_rss&amp;utm_campaign=uvmetre#comments</comments><dc:creator>uvmetre</dc:creator><title>Magnetic thickness gauges applications</title><pubDate>Mon, 20 Jul 2020 02:15:37 GMT</pubDate><description><![CDATA[Cars are closely related to our lives, and coating thickness gauges also play an important role in the automotive industry. As we all know, the thickness of a car paint is related to the quality of the car itself. Especially when buying a second-hand car, the uneven thickness of the paint may mean that the car is repainted after being worn out by impact, and the overall safety will be greatly reduced. The coating thickness gauge can detect the thickness of the non-magnetic coating on the magnetic metal substrate such as steel, and it can naturally be used to detect the thickness of the coating paint on the car. In addition, the chrome plating of the mold, the hard chrome plating of the roller, the chrome plating of the outer surface...]]></description><content:encoded><![CDATA[
  <p>Cars are closely related to our lives, and coating thickness gauges also play an important role in the automotive industry. As we all know, the thickness of a car paint is related to the quality of the car itself. Especially when buying a second-hand car, the uneven thickness of the paint may mean that the car is repainted after being worn out by impact, and the overall safety will be greatly reduced. The coating thickness gauge can detect the thickness of the non-magnetic coating on the magnetic metal substrate such as steel, and it can naturally be used to detect the thickness of the coating paint on the car. In addition, the chrome plating of the mold, the hard chrome plating of the roller, the chrome plating of the outer surface of the automobile and the accessories Galvanizing, etc. all require coating thickness testing, so that the workpiece can be more usefully cared for, and the result is really objective.<br />Coating thickness gauges are also used on a large scale in the production of steel structure products. The most important quality inspection links are inseparable from it. For example, bridges, brackets, iron towers, ship plates, including road guardrails, and printed circuit boards. , And screen printing, the use of coating thickness gauges can efficiently measure non-conductive coatings such as paint, varnish, enamel, chrome, and zinc plating, which have become a must for these manufacturers.<br />Not only the steel structure, but the current development of aluminum companies has entered a new stage. The coating thickness gauge is also of inestimable value for the aluminum profile industry. The key is to detect the oxide film on the outer surface of the aluminum profile. The oxide film is about the maintenance of the aluminum profile. Importantly, this also means that the coating thickness gauge is indispensable. After accurate measurement, not only can the production quality parameters be obtained in time, but also the material can be saved. <a href="https://www.linshangtech.com/tech/tech409.html" target="_blank">Magnetic thickness gauge</a> can be used to test the coating thickness on metal substrates.<br />Avoiding pipeline corrosion is an important part of pipeline engineering. Appropriate solutions to the outer surface of the pipeline can result in pre-corrosion. The detailed methods include painting, anti-corrosion layer, powder layer, etc. The coating thickness gauge is used to test whether the coating on the outer wall of the pipeline can meet the national standard, so as to determine whether the pipeline construction can meet the standard. The petroleum energy industry needs to use pipelines for long-term transportation. Once the coating fails to meet the standards, it will cause major economic losses. Doing a good job in inspection is a top priority. Therefore, the use of coating thickness gauges is of great significance.<br />To sum up, in the chemical, electronic, electric power, metal and other industries, the thickness measurement of the coating is the most important process necessary for the metal processing industry to implement the finished product inspection, and it is an effective way for the product to reach high-quality specifications. Coating thickness measurement Yiwan has dealt with these problems meily, improved manufacturing efficiency, and is a good assistant of the manufacturer.<br /></p>

]]></content:encoded></item><item><guid isPermaLink="true">https://teletype.in/@uvmetre/i5VqSqQHF</guid><link>https://teletype.in/@uvmetre/i5VqSqQHF?utm_source=teletype&amp;utm_medium=feed_rss&amp;utm_campaign=uvmetre</link><comments>https://teletype.in/@uvmetre/i5VqSqQHF?utm_source=teletype&amp;utm_medium=feed_rss&amp;utm_campaign=uvmetre#comments</comments><dc:creator>uvmetre</dc:creator><title>Purpose of coating thickness testing</title><pubDate>Fri, 17 Jul 2020 02:20:22 GMT</pubDate><description><![CDATA[What is the purpose of coating thickness testing?The anticorrosion coating of the steel structure is dominated by paint materials, and rubber, plastic and other materials may be used for special projects. The judgment of the anti-corrosion effect is generally based on the thickness of the coating. The anti-corrosion coating thickness test should be conducted after the coating is dried, and there should be no condensation on the surface of the component during the test; if there is a quality problem in the appearance of the component coating before testing, it should be repaired, and the coating thickness should be tested after repair.How to measure the coating thickness?]]></description><content:encoded><![CDATA[
  <p>What is the purpose of coating thickness testing?The anticorrosion coating of the steel structure is dominated by paint materials, and rubber, plastic and other materials may be used for special projects. The judgment of the anti-corrosion effect is generally based on the thickness of the coating. The anti-corrosion coating thickness test should be conducted after the coating is dried, and there should be no condensation on the surface of the component during the test; if there is a quality problem in the appearance of the component coating before testing, it should be repaired, and the coating thickness should be tested after repair.How to measure the coating thickness?</p>
  <p>At present, the coating thickness testing methods mainly include the magnetic method, the eddy current method, and the supergene thickness measurement method. For specific testing methods, see &quot;Technical Standards for On-site Testing of Steel Structures&quot; (GB/T 50621-2010). When measuring, the maximum range of the coating thickness gauge is generally 1000-1500μm, the minimum resolution is usually 1-2μm, and the relative error of the indicated value should not be greater than 3%. The radius of curvature of the test component should meet the requirements of the instrument. When measuring the surface during bending time, the influence of the curvature on the test accuracy should be considered. The same component shall be tested at 5 points, and each point shall be tested at 3 measuring points 50mm apart. The coating at the measuring point should be well adhered to the steel. When using a <a href="https://www.linshangtech.com/product/LS220H_EN.html" target="_blank">paint thickness gauge</a>, electromagnetic interference should be avoided.</p>

]]></content:encoded></item><item><guid isPermaLink="true">https://teletype.in/@uvmetre/47IBkjF3t</guid><link>https://teletype.in/@uvmetre/47IBkjF3t?utm_source=teletype&amp;utm_medium=feed_rss&amp;utm_campaign=uvmetre</link><comments>https://teletype.in/@uvmetre/47IBkjF3t?utm_source=teletype&amp;utm_medium=feed_rss&amp;utm_campaign=uvmetre#comments</comments><dc:creator>uvmetre</dc:creator><title>High precision coating thickness gauge</title><pubDate>Thu, 16 Jul 2020 02:25:24 GMT</pubDate><description><![CDATA[Linshang LS223 high-precision coating thickness gauge is a dual-purpose iron and aluminum instrument, suitable for the measurement of non-magnetic coatings on ferromagnetic metal substrates such as iron and steel, and can also be used for non-magnetic coatings on non-magnetic metal substrates such as copper and aluminum. Measurement of conductive coatings. The measurement accuracy of the high-precision coating thickness gauge is: ≤±(3% reading+2μm): 0-3000μm ≤±(5% reading+2μm): 3000μm-5000μm Measuring method of high-precision coating thickness gauge Tools/raw materials High-precision coating thickness gauge Iron-based materials Non-ferrous materials Method/Step 1 First, press and hold the power button to enter the setting mode when...]]></description><content:encoded><![CDATA[
  <p>Linshang LS223 high-precision <a href="https://www.linshangtech.com/tech/uv-dosimeter-tech1370.html" target="_blank">coating thickness gauge</a> is a dual-purpose iron and aluminum instrument, suitable for the measurement of non-magnetic coatings on ferromagnetic metal substrates such as iron and steel, and can also be used for non-magnetic coatings on non-magnetic metal substrates such as copper and aluminum. Measurement of conductive coatings.<br />The measurement accuracy of the high-precision coating thickness gauge is:<br />  ≤±(3% reading+2μm): 0-3000μm<br />≤±(5% reading+2μm): 3000μm-5000μm<br />Measuring method of high-precision coating thickness gauge<br />Tools/raw materials<br />High-precision coating thickness gauge<br />Iron-based materials<br />Non-ferrous materials<br />Method/Step<br />1<br />First, press and hold the power button to enter the setting mode when the instrument is turned off, and use the buttons to select the NFe/Fe automatic recognition mode.<br />Measuring method of high-precision coating thickness gauge<br />2<br />Then you can start the test. First, check the coating thickness of a non-ferrous base material. When the probe touches the material to be tested, it will switch to the NFe mode. After another measurement, the data can be measured. The coating thickness of the iron-based material is 24.2 μm.<br />Measuring method of high-precision coating thickness gauge<br />3<br />Then detect the coating thickness of an iron-based material. When the probe touches the object to be tested, it will immediately switch to the Fe mode. The data can be measured again. As shown in the figure, the coating thickness of the iron-based material is 4.93 mm.<br />Measuring method of high-precision coating thickness gauge<br />Precautions<br />When the measurement mode is selected, the cursor stays for more than 3 seconds is regarded as OK<br />When changing the substrate, zero can be adjusted to ensure accurate data<br /></p>

]]></content:encoded></item><item><guid isPermaLink="true">https://teletype.in/@uvmetre/ypx3Sx-JY</guid><link>https://teletype.in/@uvmetre/ypx3Sx-JY?utm_source=teletype&amp;utm_medium=feed_rss&amp;utm_campaign=uvmetre</link><comments>https://teletype.in/@uvmetre/ypx3Sx-JY?utm_source=teletype&amp;utm_medium=feed_rss&amp;utm_campaign=uvmetre#comments</comments><dc:creator>uvmetre</dc:creator><title>UVC meter test uv lamp intensity</title><pubDate>Wed, 15 Jul 2020 02:22:28 GMT</pubDate><description><![CDATA[As a kind of light pollution, ultraviolet rays have always been considered as harmful light, and this is indeed the case. The absorption of ultraviolet rays through the skin can damage DNA (the chemical transport unit that makes up the transmission of chromosomal genes). When DNA is damaged, the cells will die or develop into uncontrollable cancer cells. This is the initial stage of tumor formation.According to the size of UV damage, people divided the UV into different levels. Ultraviolet intensity is generally expressed as 0-15. It is usually stipulated that the UV index at night is 0, and the UV is the strongest in the tropical or plateau area and when there is no cloud on a sunny day. It can be seen that the larger the value of the...]]></description><content:encoded><![CDATA[
  <p>As a kind of light pollution, ultraviolet rays have always been considered as harmful light, and this is indeed the case. The absorption of ultraviolet rays through the skin can damage DNA (the chemical transport unit that makes up the transmission of chromosomal genes). When DNA is damaged, the cells will die or develop into uncontrollable cancer cells. This is the initial stage of tumor formation.According to the size of UV damage, people divided the UV into different levels. Ultraviolet intensity is generally expressed as 0-15. It is usually stipulated that the UV index at night is 0, and the UV is the strongest in the tropical or plateau area and when there is no cloud on a sunny day. It can be seen that the larger the value of the ultraviolet index, the greater the harm of ultraviolet radiation to the human body, and the stronger the damage to the skin in a shorter time. Sometimes, the UV index can be divided into 5 levels, that is, when the index value is 0, 1, 2, it is level 1, which means that the minimum amount of ultraviolet radiation in solar radiation has little effect on the human body; when the UV index is 3, 4, Level 2, which means that the amount of ultraviolet radiation in the solar radiation is relatively low, and the impact on the human body is relatively small; when the ultraviolet index is 5, 6, it can be called level 3, indicating that the ultraviolet radiation is of medium intensity, which has a certain degree of damage to human skin; When the UV index is 7, 8, or 9, it can be regarded as level 4, indicating that the ultraviolet radiation is strong, which is harmful to the human body, and attention should be paid to prevent it; when you go out, you should wear a sun hat, sunglasses or parasol, and you can also apply some sunscreen (The SPF index should be greater than 15). When the UV index ≥10, it can be regarded as grade 5, indicating that the ultraviolet radiation is the strongest and the most harmful to the human body. People should reduce the time of going out (especially around noon), or take active protective measures.</p>
  <p>Therefore, we usually need to regularly check the UV level around us in our daily lives. In general, the detection level requires professional equipment, such as <a href="https://www.linshangtech.com/tech/how-to-select-the-best-uv-light-meter-for-your-application-tech1166.html" target="_blank">UVC meter</a>, spectroradiometer, etc.</p>

]]></content:encoded></item><item><guid isPermaLink="true">https://teletype.in/@uvmetre/hMmK9oWOS</guid><link>https://teletype.in/@uvmetre/hMmK9oWOS?utm_source=teletype&amp;utm_medium=feed_rss&amp;utm_campaign=uvmetre</link><comments>https://teletype.in/@uvmetre/hMmK9oWOS?utm_source=teletype&amp;utm_medium=feed_rss&amp;utm_campaign=uvmetre#comments</comments><dc:creator>uvmetre</dc:creator><title>Working principle of UV dosimeter</title><pubDate>Tue, 14 Jul 2020 03:02:20 GMT</pubDate><description><![CDATA[The working principle of the UV dosimeter: First of all, we must first understand what is the light intensity. The light intensity refers to the degree of the object being illuminated, that is, the ratio of the light flux on the surface of the object to the area being illuminated. Ultraviolet UV illuminance meter, also known as ultraviolet radiometer, ultraviolet irradiance meter, ultraviolet intensity meter, etc., is an instrument specially used to measure light intensity and brightness. The instrument is mainly used to measure ultraviolet rays, used in photochemistry, polymer material aging, flaw detection , Health, medical, chemical, health, food, electronics, plant cultivation, large-scale integrated circuit lithography and other...]]></description><content:encoded><![CDATA[
  <p>The working principle of the <a href="https://www.linshangtech.com/tech/uv-dosimeter-tech1370.html" target="_blank">UV dosimeter</a>: First of all, we must first understand what is the light intensity. The light intensity refers to the degree of the object being illuminated, that is, the ratio of the light flux on the surface of the object to the area being illuminated. Ultraviolet UV illuminance meter, also known as ultraviolet radiometer, ultraviolet irradiance meter, ultraviolet intensity meter, etc., is an instrument specially used to measure light intensity and brightness. The instrument is mainly used to measure ultraviolet rays, used in photochemistry, polymer material aging, flaw detection , Health, medical, chemical, health, food, electronics, plant cultivation, large-scale integrated circuit lithography and other fields of ultraviolet radiation measurement work.<br />The UV dosimeter uses 35 different probes to measure UVA, UVB, UVC, visible light and infrared light. The measurement wavelength is divided into UVA (320nm-380nm), UVB (280nm-320nm), UVC (200nm-280nm), and some high-end products can detect a wide range of bands. Humanized operation, small and flexible, easy to carry.<br />Photovoltaic cells are photovoltaic elements that can directly convert light energy into electrical energy. Therefore, when the light hits the surface of the selenium photovoltaic cell, the incident light passes through the metal thin film and reaches the interface between the semiconductor selenium layer and the metal thin film, and a photoelectric effect is generated when passing through the interface. Then there is a potential difference, and the magnitude of this difference has a certain proportional relationship with the intensity of the illuminance on the photovoltaic cell surface. If an external circuit is connected at this time, a current will flow through, and the current value can be displayed on the microamp meter. The magnitude of photocurrent is the intensity of light and the magnitude of resistance in the loop. The illuminance meter has a shift device, so it can measure high illuminance and low illuminance.<br />Shenzhen Linshang Technology, as a manufacturer of ultraviolet radiation illuminance meter, provides you with a series of ultraviolet radiation illuminance meters, covering germicidal lamp ultraviolet intensity detector, multi-probe ultraviolet illuminance meter, digital intelligent ultraviolet power meter that can be monitored online, etc. Can provide you with UVA, UVB, UVC and other wavelengths of ultraviolet intensity detection, you can freely choose a host with a probe or a host with multiple probes. The operation of the instrument is simple and fast, and the measurement data is accurate, which can be tested by the national authoritative measurement agency.</p>

]]></content:encoded></item><item><guid isPermaLink="true">https://teletype.in/@uvmetre/cOyk4mAOm</guid><link>https://teletype.in/@uvmetre/cOyk4mAOm?utm_source=teletype&amp;utm_medium=feed_rss&amp;utm_campaign=uvmetre</link><comments>https://teletype.in/@uvmetre/cOyk4mAOm?utm_source=teletype&amp;utm_medium=feed_rss&amp;utm_campaign=uvmetre#comments</comments><dc:creator>uvmetre</dc:creator><title>Transmittance tester used to test the performance of car film</title><pubDate>Tue, 09 Jun 2020 06:52:14 GMT</pubDate><description><![CDATA[Some main performance indicators of automobile heat insulation film: Visible light transmittance: Referred to as light transmittance, it is used to measure the percentage of visible light passing through the glass. The front barrier is generally more than 70%, and the side rear barrier is generally 5%-60%. The worse the ability, the darker the relative film color. UV rejection rate: high-quality automotive film, this index is generally not less than 98%, the highest can reach 100%. The high ultraviolet blocking rate can effectively prevent people in the car from being irradiated by excessive ultraviolet rays and burning the skin. Many inferior membranes do not have this index, or are far below the 98% standard. Infrared rejection rate:...]]></description><content:encoded><![CDATA[
  <p>Some main performance indicators of automobile heat insulation film: Visible light transmittance: Referred to as light transmittance, it is used to measure the percentage of visible light passing through the glass. The front barrier is generally more than 70%, and the side rear barrier is generally 5%-60%. The worse the ability, the darker the relative film color. UV rejection rate: high-quality automotive film, this index is generally not less than 98%, the highest can reach 100%. The high ultraviolet blocking rate can effectively prevent people in the car from being irradiated by excessive ultraviolet rays and burning the skin. Many inferior membranes do not have this index, or are far below the 98% standard. Infrared rejection rate: Infrared is also a part of sunlight. Most of the heat of light is transmitted through infrared. Compared with automotive glass films, the higher the percentage, the better the thermal insulation effect. Total thermal insulation rate: The total thermal insulation rate of professional thermal insulation film can generally reach 40%-79%. It is a value synthesized by various indicators of the glass film. Some merchants usually confuse the concept and often use the concept of &quot;infrared barrier rate&quot; to pretend to be &quot;insulation rate&quot;. This is not correct. Visible light reflectance: Unlike visible light transmittance, higher reflectance will directly reflect the irradiated light back, similar to a mirror. The higher the reflectivity, the stronger the privacy of the glass film and the better the heat insulation.<br /> <a href="https://accounts.google.com/ServiceLogin?service=blogger&passive=1209600&continue=https://www.blogger.com/blog/post/edit/242548318951072663/433592750729150638&followup=https://www.blogger.com/blog/post/edit/242548318951072663/433592750729150638" target="_blank">Transmittance tester</a> is a professional instrument used to test the visible light transmittance, IR rejection rate and UV rejection rate.</p>